Vui lòng dùng định danh này để trích dẫn hoặc liên kết đến tài liệu này:
http://thuvienso.vanlanguni.edu.vn/handle/Vanlang_TV/18486
Nhan đề: | Experimental Research on Antiseismic Performance of High-Strength Concrete High-Shear Walls with Built-In Steel Plates |
Tác giả: | Yu, Yu Gan, Min Zhang, Yan Li, Liren Zhang, Huakun |
Từ khoá: | Steel ratios Construction Concrete construction High strength concretes High rise buildings Failure mechanisms Seismic response Studies Concrete Failure modes Civil engineering Compression tests Crack initiation Earthquakes Aseismic buildings Cracks Seismic engineering Steel plates Reinforced concrete Shear walls Bearing capacity Compression ratio |
Năm xuất bản: | 2019 |
Nhà xuất bản: | Hindawi Limited |
Tóm tắt: | To study the antiseismic performance of the high-strength concrete composite shear wall with built-in steel plates, an experiment on a high-strength concrete composite shear wall with four built-in steel plates (SPRCW-1∼4) was set up. Based on the experimental result, the paper discusses the antiseismic performance, failure mode, and failure mechanism of the high-strength concrete composite shear wall with built-in steel plates under different steel ratios and different positions of steel plates. The experimental result has shown that the differences in steel plate position and steel ratios have certain effects on wall cracking. The use of high steel content and the placement of steel plates on both sides of the wall can limit wall cracking to some extent. When the bearing capacity of the steel plates located on both sides of the wall is larger than that in the middle of the wall, a high content of steel in the wall can effectively increase the bearing capacity of the test piece to some extent. Under a high axial compression ratio, the horizontal bar of the wall can substantially limit the vertical cracks in concrete arising from compression. Moreover, the built-in steel plates in the shear wall play a significant role in inhibiting the propaganda of the oblique cracks under the action of earthquakes. The research result has very good economy and operability and can provide a basis for promotion and application of the mid- and high-rise buildings in regions with high seismic intensity. |
Mô tả: | Advances in Civil Engineering; New York Vol. 2019, (2019). DOI:10.1155/2019/4769404 |
Định danh: | http://thuvienso.vanlanguni.edu.vn/handle/Vanlang_TV/18486 |
ISSN: | 1687-8086 1687-8094 (eISSN) |
Bộ sưu tập: | Bài báo_lưu trữ |
Các tập tin trong tài liệu này:
Tập tin | Mô tả | Kích thước | Định dạng | |
---|---|---|---|---|
BBKH1208_TCCN_Experimental Research on ....pdf Giới hạn truy cập | "Experimental Research on Antiseismic Performance of High-Strength Concrete High-Shear Walls with Built-In Steel Plates " | 17.37 MB | Adobe PDF | Xem/Tải về Yêu cầu tài liệu |
Khi sử dụng các tài liệu trong Thư viện số phải tuân thủ Luật bản quyền.