Vui lòng dùng định danh này để trích dẫn hoặc liên kết đến tài liệu này:
http://thuvienso.vanlanguni.edu.vn/handle/Vanlang_TV/18800
Toàn bộ biểu ghi siêu dữ liệu
Trường DC | Giá trị | Ngôn ngữ |
---|---|---|
dc.contributor.author | Yazdani, Nur | - |
dc.contributor.author | Beneberu, Eyosias | - |
dc.contributor.author | Riad, Mina | - |
dc.date.accessioned | 2020-06-01T11:03:04Z | - |
dc.date.available | 2020-06-01T11:03:04Z | - |
dc.date.issued | 2019 | - |
dc.identifier.issn | 1687-8086 | - |
dc.identifier.issn | 1687-8094 (eISSN) | - |
dc.identifier.other | BBKH1397 | - |
dc.identifier.uri | http://thuvienso.vanlanguni.edu.vn/handle/Vanlang_TV/18800 | - |
dc.description | "Hindawi; Advances in Civil Engineering; Volume 2019, Article ID 2563079, 10 pages; https://doi.org/10.1155/2019/2563079" | vi |
dc.description.abstract | Carbon fiber-reinforced polymer (CFRP) laminates have been successfully used as externally bonded reinforcements for retrofitting, strengthening, and confinement of concrete structures. The adequacy of the CFRP-concrete bonding largely depends on the bond quality and integrity. The bond quality may be compromised during the CFRP installation process due to various factors. In this study, the effect of four such construction-related factors was assessed through nondestructive evaluation (NDE) methods, and quantification of the levels of CFRP debonding was achieved. The factors were surface cleanliness, surface wetness, upward vs. downward application, and surface voids. A common unidirectional CFRP was applied to small-scale concrete samples with factorial combinations. Ground-penetrating radar and thermography NDE methods were applied to detect possible disbonds at CFRP-concrete interfaces. Thermography was found to clearly detect all four factors, while the GPR was only effective for detecting the surface voids only. The thermal images overpredicted the amount of debonded CFRP areas by about 25%, possibly due to scaling errors between the thermograph and the sample surface. The maximum debonded CFRP area in any sample was about two percent of the total CFRP area. This is a negligible amount of debonding, showing that the factors considered are unlikely to significantly affect the laminate performance or any CFRP contribution to the concrete member strength or confinement. | vi |
dc.language.iso | en | vi |
dc.publisher | Hindawi Limited | vi |
dc.subject | Laboratories | vi |
dc.subject | Nondestructive testing | vi |
dc.subject | Defects | vi |
dc.subject | Bubbles | vi |
dc.subject | Concrete | vi |
dc.subject | Concrete structures | vi |
dc.subject | Surface wetness | vi |
dc.subject | Bonding strength | vi |
dc.subject | Thermography | vi |
dc.subject | Laminates | vi |
dc.subject | Moisture content | vi |
dc.subject | Surface defects | vi |
dc.subject | Delamination | vi |
dc.subject | Quality | vi |
dc.subject | Composite materials | vi |
dc.subject | Polymers | vi |
dc.subject | Adequacy | vi |
dc.subject | Cameras | vi |
dc.subject | Concrete reinforcements | vi |
dc.subject | Debonding | vi |
dc.subject | Civil engineering | vi |
dc.subject | Ground penetrating radar | vi |
dc.title | Nondestructive Evaluation of FRP-Concrete Interface Bond due to Surface Defects | vi |
dc.type | Other | vi |
Bộ sưu tập: | Bài báo_lưu trữ |
Các tập tin trong tài liệu này:
Tập tin | Mô tả | Kích thước | Định dạng | |
---|---|---|---|---|
BBKH1397_TCCN_Nondestructive Evaluation of FRP.pdf Giới hạn truy cập | Nondestructive Evaluation of FRP-Concrete Interface Bond due to Surface Defects | 5.85 MB | Adobe PDF | Xem/Tải về Yêu cầu tài liệu |
Khi sử dụng các tài liệu trong Thư viện số phải tuân thủ Luật bản quyền.